64. Which two statements are true about setting the FAST_START_MTTR_TARGET initialization
parameter to a nonzero value? (Choose two.)
A.The MTTR advisor will be disabled.
B.Automatic checkpoint tuning will be enabled.
C.The value for the LOG_CHECKPOINT_INTERVAL initialization parameter will be override the value for
FAST_START_MTTR_TARGET.
D.The time taken to recover the instance after the crash is always exactly the same as the value given for
the FAST_START_MTTR_TARGET initialization parameter.
Answer: BC
答案解析:
参考:/article/1629004.html
A。 MTTR advisor禁用,错误。

To enable MTTR Advisor, set the two initialization parameters
STATISTICS_LEVEL
and
FAST_START_MTTR_TARGET
.

STATISTICS_LEVEL
governs whether all advisors are enabled and is not specific to MTTR Advisor. Ensure that it is set to
TYPICAL
or
ALL
. Then, when
FAST_START_MTTR_TARGET
is set
to a nonzero value, the MTTR Advisor is enabled.

故A错误。

MTTR 指导可将FAST_START_MTTR_TARGET值转换为多个参数,以便在所需时间内(或者在尽量接近此时间的范围内)启用实例恢复。请注意,将禁用
FAST_START_MTTR_TARGET参数显式设置为0会禁用MTTR 指导。

故D错误。是在所需时间内或在尽量接近此事件的范围内,并不是指定的时间点。

FAST_START_MTTR_TARGET参数的设置值必须支持系统的服务级协议。如果MTTR 目标的值较小,则会因增加了数据文件写入次数而增加I/O 开销(这会影响性能)。但是,如果MTTR 目标设置得过大,则实例在崩溃后需要花费较长的时间才会恢复。

而快速启动检查点功能是通过指定所需的非零恢复平均时间(MTTR)值来启用的,该值将用于设置FAST_START_MTTR_TARGET初始化参数。此参数控制数据库对单个实例执行崩溃恢复所花费的时间量。启用快速启动检查点功能时,oracle将自动保持检查点的速度,已便达到请求的MTTR.如果将该值设置为0,将禁用此功能。
故B正确。

FAST_START_MTTR_TARGET
enables you to specify the number of seconds the database takes to perform crash recovery of a single instance. When specified,
FAST_START_MTTR_TARGET
is
overridden by
LOG_CHECKPOINT_INTERVAL
.

FAST_START_MTTR_TARGET
会被
LOG_CHECKPOINT_INTERVAL所覆盖,故C正确。

官方参考:http://docs.oracle.com/cd/E11882_01/server.112/e40402/initparams090.htm#sthref268



Automatic Checkpoint Tuning in 10g [ID 265831.1]
How to enable:
Automatic checkpoint tuning is enabled by default. If it is disabled, by setting the
parameter to zero explicitly, you can enable it by unsetting FAST_START_MTTR_TARGET or
set it to a nonzero value. If you set this parameter to zero this feature will be disabled.
Note: this is different from defaulting (i.e. not setting) fast_start_mttr_target to 0