您的位置:首页 > 运维架构

SBL-SCM-00018: Could not open connection to Siebel Gateway configuration store

2013-03-17 23:15 1346 查看
Siebel Configuration Wizard Fails With Error, "SBL-SCM-00018: Could not open connection to Siebel
Gateway configuration store" [ID 870263.1]


转到底部

修改时间:2013-3-6

类型:PROBLEM

状态:PUBLISHED

优先级:3

注释
(0)



















In this Document

Symptoms
Cause
Solution

Applies to:

Siebel CRM - Version 8.0 [20405] to 8.2.2.2 SIA[23016] [Release V8]

Information in this document applies to any platform.

***Checked for relevance on 06-Mar-2013***

Symptoms

When Running the Siebel Server Configurator, It Fails Showing the Error: "SBL-SCM-00018: Could not open connection to Siebel Gateway configuration store"

Cause

There is an error with the DB parameters during the Gateway and Enterprise configuration.

The configurator cannot locate a login (because it cannot reach the DB), so the Server configurator fails to start

Solution

Steps to solve the issue:

- Run the Gateway configurator

- Delete the Enterprise configuration

- Run the Gateway configuration again

- Delete the Gateway server

- Create a new Gateway server, checking that the DB server and hostname are correct

- Create a new Enterprise, checking that the DB server and hostname are correct.

- Run the Siebel server configurator