Error: "Unable to control A20 line" when starting Ghost.exe
Situation: | When you run Ghost.exe, you see the message "Causeway error 07: unable to control A20 line." |
Solution: | This message indicates a problem with the Himem.sys file. If the problem occurs after you "warm boot" the computer, it is usually eliminated by a "cold boot." Before trying any of the following solutions, turn off the computer, wait 30 seconds, and then turn the computer on again. Turning off the computer flushes memory, which might allow the Himem.sys file to load correctly. NOTE: For a detailed explanation of Himem.sys and warm and cold boots, see "Technical explanation of the messages" later in this document. This problem is most often caused by the computer's CPU using a nonstandard type of memory management. To resolve this problem, add the lines Device=A:\Himem.sys and Set DOS16M=2 to the Config.sys and Autoexec.bat files, respectively. See the section "How to edit the Config.sys and Autoexec.bat startup files" later in this document. If adding those lines to the startup files does not resolve the problem, check the following possibilities: The Himem.sys file is not in the directory in which the computer expects to find it. Make sure that Himem.sys is in the same directory as Ghost.exe or in the root of the bootable floppy disk from which you are running Ghost. The Config.sys file is attempting to load the Himem.sys file more than once. When the Config.sys file calls the Himem.sys file more than once, the computer can become confused. In this case, edit the Config.sys file to remove all references (calls) to Himem.sys except one. The Himem.sys file is damaged. Delete the copy of Himem.sys from the bootable floppy disk, and replace it with a fresh copy from the same version of DOS. How to edit the Config.sys and Autoexec.bat startup files This procedure modifies the Config.sys and Autoexec.bat files to accommodate different types of memory handling used by the CPU. Since a variety of memory handling methods are in use, you may need to repeat this procedure several times to find the modification necessary for the particular CPU on your computer, as described in Step 9. To modify the startup files to accommodate different types of memory handling:Restart the computer. Do one of the following: For Windows 95: When the message "Starting Windows 95" appears, immediately press F8. The Windows 95 Startup Menu appears. For Windows 98: Hold down the Ctrl key after restarting the computer. The Windows 98 Startup menu appears. Select Safe Mode - Command Prompt Only and press Enter. The C: prompt appears. At the C: prompt, enter: EDIT Autoexec.bat The DOS Editor opens and displays the contents of the Autoexec.bat file. At the beginning of the file, press enter to create a blank line, and then type the following line: SET DOS16M=2 This command increases reserved memory blocks from 1 to 2. Press Alt+F, then X to exit the DOS Editor. When prompted to save the changes, choose Yes and press Enter. The C: prompt appears. At the C: prompt, enter: EDIT Config.sys The DOS Editor opens and displays the contents of the Config.sys file. Locate the line loading Himem.sys. For example, it may read: DEVICE=C:\Windows\Himem.sys The name and location of the Windows program folder may be different on your computer. At the end of the line, type a space, and then type the following: /M:1 The line should now read: DEVICE=C:\Windows\Himem.sys /M:1 If you do not have the Himem.sys line, add the line to the beginning of the file. Note that the /M:1 line depends upon the hardware version of the A20 handler. You may need to try the numbers 1-17 (for instance, /M:12) to find the correct version for the computer. PS/2 computers and Prolinea computers, for example, tend to require /M:2 instead of /M:1. Press Alt+F, then X to exit the DOS Editor. When prompted to save the changes, select Yes and press Enter. Restart the computer. It should now start normally. If the problem is still not resolved If none of these procedures resolved the problem, there may be physical damage to some component of the computer, such as a bad memory chip. Resolution of such issues is beyond the scope of this document. Technical explanation of A20 messages Himem.sys is a DOS program that enables access to the first 64 KB of extended memory, called "high memory." Although Windows is an operating system, it needs this file because Windows 3.x, Windows 95, and Windows 98 are not "standalone" operating systems. They require the Disk Operating System (DOS) to load and run. During computer startup, the computer first starts up in DOS. Once DOS is loaded and the computer has access to high memory, Windows can then load. If the computer does not have access to high memory, Windows cannot load and the computer will display A20 messages. The number A20 refers to the "line" of the CPU that must be enabled in order for Himem.sys to access the high memory area. The A20 error occurs when the A20 line is not enabled. Warm boot A "warm boot" means restarting the computer without first turning off the power. In DOS, a computer can be warm booted by using the Reset button or by pressing Ctrl+Alt+Del. Cold boot A "cold boot" means starting the computer by turning on the power. Generally, after turning off the power, wait 5 to 30 seconds before turning on the power again. This allows time for the hard disk to fully power down before restarting it and time for old information to "drain" from the computer. |
相关文章推荐
- SQL 2005服务启动失败(在与 SQL Server 建立连接时出现与网络相关的或特定于实例的错误)
- U盘启动不用说了,咱们来说下网络自制的PXE和GHOST网络启动
- vmware复制fedora16出现网络启动错误
- nfs启动出现网络断开Try to bring eth0 interface up....../etc/init.d/ifconfig-eth0: line 6: grep: not found
- DHCP tftp PXE实现Ghost网络克隆
- 启动tomcat是出现错误( Parse Fatal Error at line 1 column 1: Content is not allowed in prolog.)
- 关于tomcat启动出现Line: 220 - com/opensymphony/xwork2/spring/SpringObjectFactory.java:220:-1错误的解决办法
- 用 Ghost 软件实现基于 PXE 的网络硬盘克隆
- ghost实现 PXE 网络启动方式
- vmware复制fedora16出现网络启动错误
- linux(suse)oracle服务器,改变网络后,不能通过监听启动,ora-12514错误,修改listener.ora后,出现ora-01034 ora-27101
- 解决Win7启动网络共享出现错误提示1061的方法
- 启动DELPHI2007出现 EditorLineEnds.ttr 错误的解决方法
- 连接数据库与 SQL Server 建立连接时出现与网络相关的或特定于实例的错误,请验证实例名称是否正确并且 SQL Server 已配置为允许远程连接。
- 手动启动“远程过程调用”服务时,出现错误信息1058
- java项目——启动tomcat出现错误
- 在与 SQL Server 建立连接时出现与网络相关的或特定于实例的错误
- 从eclipse3.4中启动tomcat6.0.16出现有关“SetPropertiesRule”错误的问题解决方法[转载]
- 网络ghost(网络克隆)
- MySQL启动出现The server quit without updating PID file错误解决办法