未能初始化 AppDomain:/LM/W3SVC/1/Root 服务应用程序不可用
2011-11-30 15:09
190 查看
错误提示如下:
未能初始化 AppDomain:/LM/W3SVC/1/Root
Exception: System.Configuration.ConfigurationErrorsException
Message: 引发类型为“System.Configuration.ConfigurationErrorsException”的异常。
StackTrace: 在 System.Web.Configuration.ErrorRuntimeConfig.ErrorConfigRecord.System.Configuration.Internal.IInternalConfigRecord.GetLkgSection(String configKey)
在 System.Web.Configuration.RuntimeConfigLKG.GetSectionObject(String sectionName)
在 System.Web.Configuration.RuntimeConfig.GetSection(String sectionName, Type type, ResultsIndex index)
在 System.Web.Configuration.RuntimeConfig.get_HostingEnvironment()
在 System.Web.Hosting.HostingEnvironment.StartMonitoringForIdleTimeout()
在 System.Web.Hosting.HostingEnvironment.Initialize(ApplicationManager appManager, IApplicationHost appHost, IConfigMapPathFactory configMapPathFactory, HostingEnvironmentParameters hostingParameters)
在 System.Web.Hosting.HostingEnvironment.Initialize(ApplicationManager appManager, IApplicationHost appHost, IConfigMapPathFactory configMapPathFactory, HostingEnvironmentParameters hostingParameters)
在 System.Web.Hosting.ApplicationManager.CreateAppDomainWithHostingEnvironment(String appId, IApplicationHost appHost, HostingEnvironmentParameters hostingParameters)
在 System.Web.Hosting.ApplicationManager.CreateAppDomainWithHostingEnvironmentAndReportErrors(String appId, IApplicationHost appHost, HostingEnvironmentParameters hostingParameters)
有关更多信息,请参阅在 http://go.microsoft.com/fwlink/events.asp 的帮助和支持
-----------------------------------------------------------------------------
由于 ASP.NET 进程标识对全局程序集缓存没有读权限,因此未能执行请求。错误: 0x80131902
有关更多信息,请参阅在 http://go.microsoft.com/fwlink/events.asp 的帮助和支持中心。
--------------------------------------------------------------------------------
aspnet_wp.exe (PID: 4004)意外停止。
有关更多信息,请参阅在 http://go.microsoft.com/fwlink/events.asp 的帮助和支持中心。
原因分析,先安装VS,后安装IIS造成,.NET没有正确注册iis,从新注册.NET到IIS,打开cmd命令提示符,运行以下命令:
C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\aspnet_regiis.exe -i
注意最后 -i有空格,其中v4.0.30319为要注册的版本号。
未能初始化 AppDomain:/LM/W3SVC/1/Root
Exception: System.Configuration.ConfigurationErrorsException
Message: 引发类型为“System.Configuration.ConfigurationErrorsException”的异常。
StackTrace: 在 System.Web.Configuration.ErrorRuntimeConfig.ErrorConfigRecord.System.Configuration.Internal.IInternalConfigRecord.GetLkgSection(String configKey)
在 System.Web.Configuration.RuntimeConfigLKG.GetSectionObject(String sectionName)
在 System.Web.Configuration.RuntimeConfig.GetSection(String sectionName, Type type, ResultsIndex index)
在 System.Web.Configuration.RuntimeConfig.get_HostingEnvironment()
在 System.Web.Hosting.HostingEnvironment.StartMonitoringForIdleTimeout()
在 System.Web.Hosting.HostingEnvironment.Initialize(ApplicationManager appManager, IApplicationHost appHost, IConfigMapPathFactory configMapPathFactory, HostingEnvironmentParameters hostingParameters)
在 System.Web.Hosting.HostingEnvironment.Initialize(ApplicationManager appManager, IApplicationHost appHost, IConfigMapPathFactory configMapPathFactory, HostingEnvironmentParameters hostingParameters)
在 System.Web.Hosting.ApplicationManager.CreateAppDomainWithHostingEnvironment(String appId, IApplicationHost appHost, HostingEnvironmentParameters hostingParameters)
在 System.Web.Hosting.ApplicationManager.CreateAppDomainWithHostingEnvironmentAndReportErrors(String appId, IApplicationHost appHost, HostingEnvironmentParameters hostingParameters)
有关更多信息,请参阅在 http://go.microsoft.com/fwlink/events.asp 的帮助和支持
-----------------------------------------------------------------------------
由于 ASP.NET 进程标识对全局程序集缓存没有读权限,因此未能执行请求。错误: 0x80131902
有关更多信息,请参阅在 http://go.microsoft.com/fwlink/events.asp 的帮助和支持中心。
--------------------------------------------------------------------------------
aspnet_wp.exe (PID: 4004)意外停止。
有关更多信息,请参阅在 http://go.microsoft.com/fwlink/events.asp 的帮助和支持中心。
原因分析,先安装VS,后安装IIS造成,.NET没有正确注册iis,从新注册.NET到IIS,打开cmd命令提示符,运行以下命令:
C:\WINDOWS\Microsoft.NET\Framework\v4.0.30319\aspnet_regiis.exe -i
注意最后 -i有空格,其中v4.0.30319为要注册的版本号。
相关文章推荐
- 未能初始化 AppDomain:/LM/W3SVC/1/Root 服务应用程序不可用
- 未能初始化 AppDomain:/LM/W3SVC/1/Root 导致的服务器应用程序不可用
- 未能初始化 AppDomain:/LM/W3SVC/1/ROOT 解决之道!
- 未能初始化 AppDomain:/LM/W3SVC/1/ROOT 解决之道!
- 未能初始化 AppDomain:/LM/W3SVC/1/Root,未能加载文件或程序集“System.Web....”的解决方案
- ASP.NET安装错-未能初始化 AppDomain:/LM/W3SVC/1/Root/XXX
- C# App.config 自定义 配置节 出现的问题:配置系统未能初始化
- asp.Net 服务应用程序不可用
- 关于hadoop namenode初始化失败显示localhost.localdomain: 未知的名称或服务解决办法。
- Android 从硬件到应用程序:一步一步爬上去 6 -- 我写的APP测试框架层硬件服务(终点)
- App.config提示错误“配置系统未能初始化”
- 服务器应用程序不可用,由于无法创建应用程序域,因此未能执行请求。错误: 0x80070002 系统找不到指定的文件。
- tiny210 hal 6 Android系统中编写APP通过应用程序框架层访问硬件服务。
- C# 读取app.config配置文件 节点键值,提示 "配置系统未能初始化" 错误的解决方案
- android官方文档---应用程序基础---服务的理解(app Component---services)
- 服务 在初始化安装时发生异常:System.IO.FileNotFoundException: 未能加载文件或******
- iis布置asp.net网站——服务应用程序不可用
- IIS服务应用程序不可用
- C# App.config 自定义 配置节 报错“配置系统未能初始化” 解决方法
- ASP.net 服务应用程序不可用 解决办法