java中使用ibatis来调用存储过程(下)
2010-03-02 15:12
267 查看
3.3 游标循环最佳策略
我们在进行PL/SQL编程时,经常需要循环读取结果集的数据。进行逐行处理,这个过程就需要对游标进行循环。对游标进行循环的方法有多种,我们在此一一分析。
create or replace procedure proccycle(p varchar2)
as
cursor c_postype is select pos_type, description from pos_type_tbl where rownum <
6;
v_postype varchar2(20);
v_description varchar2(50);
begin
open c_postype;
if c_postype%found then
dbms_output.put_line('found true');
elsif c_postype%found = false then
dbms_output.put_line('found false');
else
dbms_output.put_line('found null');
end if;
loop
fetch c_postype into v_postype,v_description ;
exit when c_postype%notfound;
dbms_output.put_line('postype:'||v_postype||',description:'||v_description);
end loop;
close c_postype;
dbms_output.put_line('---loop end---');
open c_postype;
fetch c_postype into v_postype,v_description;
while c_postype%found loop
dbms_output.put_line('postype:'||v_postype||',description:'||v_description);
fetch c_postype into v_postype,v_description ;
end loop;
close c_postype;
dbms_output.put_line('---while end---');
for v_pos in c_postype loop
v_postype := v_pos.pos_type;
v_description := v_pos.description;
dbms_output.put_line('postype:'||v_postype||',description:'||v_description);
end loop;
dbms_output.put_line('---for end---');
end;
使用游标之前需要开打游标,open cursor,循环完后再关闭游标close cursor.
这是使用游标应该慎记于心的法则。
上面的过程演示了游标循环的三种方法。
在讨论循环方法之前,我们先看看%found和%notfound这些游标的属性。
open c_postype;
if c_postype%found then
dbms_output.put_line('found true');
elsif c_postype%found = false then
dbms_output.put_line('found false');
else
dbms_output.put_line('found null');
end if;
在打开一个游标之后,马上检查它的%found或%notfound属性,它得到的结果即不是true也不是false.而是null.必须执行一条fetch语句后,这些属性才有值。
第一种使用loop 循环
loop
fetch c_postype into v_postype,v_description ;
exit when c_postype%notfound;
……
end loop
这里需要注意,exit when语句一定要紧跟在fetch之后。必避免多余的数据处理。
处理逻辑需要跟在exit when之后。这一点需要多加小心。
循环结束后要记得关闭游标。
第二种使用while循环。
fetch c_postype into v_postype,v_description;
while c_postype%found loop
……
fetch c_postype into v_postype,v_description ;
end loop;
我们知道了一个游标打开后,必须执行一次fetch语句,游标的属性才会起作用。所以使用while 循环时,就需要在循环之前进行一次fetch动作。
而且数据处理动作必须放在循环体内的fetch方法之前。循环体内的fetch方法要放在最后。否则就会多处理一次。这一点也要非常的小心。
总之,使用while来循环处理游标是最复杂的方法。
第三种 for循环
for v_pos in c_postype loop
v_postype := v_pos.pos_type;
v_description := v_pos.description;
…
end loop;
可见for循环是比较简单实用的方法。
首先,它会自动open和close游标。解决了你忘记打开或关闭游标的烦恼。
其它,自动定义了一个记录类型及声明该类型的变量,并自动fetch数据到这个变量中。
我们需要注意v_pos 这个变量无需要在循环外进行声明,无需要为其指定数据类型。
它应该是一个记录类型,具体的结构是由游标决定的。
这个变量的作用域仅仅是在循环体内。
把v_pos看作一个记录变量就可以了,如果要获得某一个值就像调用记录一样就可以了。
如v_pos.pos_type
由此可见,for循环是用来循环游标的最好方法。高效,简洁,安全。
但遗憾的是,常常见到的却是第一种方法。所以从今之后得改变这个习惯了。
3.4 select into不可乎视的问题
我们知道在pl/sql中要想从数据表中向变量赋值,需要使用select into 子句。
但是它会带动来一些问题,如果查询没有记录时,会抛出no_data_found异常。
如果有多条记录时,会抛出too_many_rows异常。
这个是比较糟糕的。一旦抛出了异常,就会让过程中断。特别是no_data_found这种异常,没有严重到要让程序中断的地步,可以完全交给由程序进行处理。
create or replace procedure procexception(p varchar2)
as
v_postype varchar2(20);
begin
select pos_type into v_postype from pos_type_tbl where 1=0;
dbms_output.put_line(v_postype);
end;
执行这个过程
SQL> exec procexception('a');
报错
ORA-01403: no data found
ORA-06512: at
"LIFEMAN.PROCEXCEPTION", line
6
ORA-06512: at line
1
处理这个有三个办法
1. 直接加上异常处理。
create or replace procedure procexception(p varchar2)
as
v_postype varchar2(20);
begin
select pos_type into v_postype from pos_type_tbl where 1=0;
dbms_output.put_line(v_postype);
exception
when no_data_found then
dbms_output.put_line('没找到数据');
end;
这样做换汤不换药,程序仍然被中断。可能这样不是我们所想要的。
2. select into做为一个独立的块,在这个块中进行异常处理
create or replace procedure procexception(p varchar2)
as
v_postype varchar2(20);
begin
begin
select pos_type into v_postype from pos_type_tbl where 1=0;
dbms_output.put_line(v_postype);
exception
when no_data_found then
v_postype := '';
end;
dbms_output.put_line(v_postype);
end;
这是一种比较好的处理方式了。不会因为这个异常而引起程序中断。
3.使用游标
create or replace procedure procexception(p varchar2)
as
v_postype varchar2(20);
cursor c_postype is select pos_type from pos_type_tbl where
1=0;
begin
open c_postype;
fetch c_postype into v_postype;
close c_postype;
dbms_output.put_line(v_postype);
end;
这样就完全的避免了no_data_found异常。完全交由程序员来进行控制了。
第二种情况是too_many_rows 异常的问题。
Too_many_rows 这个问题比起no_data_found要复杂一些。
给一个变量赋值时,但是查询结果有多个记录。
处理这种问题也有两种情况:
1. 多条数据是可以接受的,也就是说从结果集中随便取一个值就行。这种情况应该很极端了吧,如果出现这种情况,也说明了程序的严谨性存在问题。
2. 多条数据是不可以被接受的,在这种情况肯定是程序的逻辑出了问题,也说是说原来根本就不会想到它会产生多条记录。
对于第一种情况,就必须采用游标来处理,而对于第二种情况就必须使用内部块来处理,重新抛出异常。
多条数据可以接受,随便取一条,这个跟no_data_found的处理方式一样,使用游标。
我这里仅说第二种情况,不可接受多条数据,但是不要忘了处理no_data_found哦。这就不能使用游标了,必须使用内部块。
create or replace procedure procexception2(p varchar2)
as
v_postype varchar2(20);
begin
begin
select pos_type into v_postype from pos_type_tbl where rownum <
5;
exception
when no_data_found then
v_postype :=null;
when too_many_rows then
raise_application_error(-20000,'对v_postype赋值时,找到多条数据');
end;
dbms_output.put_line(v_postype);
end;
需要注意的是一定要加上对no_data_found的处理,对出现多条记录的情况则继续抛出异常,让上一层来处理。
总之对于select into的语句需要注意这两种情况了。需要妥当处理啊。
我们在进行PL/SQL编程时,经常需要循环读取结果集的数据。进行逐行处理,这个过程就需要对游标进行循环。对游标进行循环的方法有多种,我们在此一一分析。
create or replace procedure proccycle(p varchar2)
as
cursor c_postype is select pos_type, description from pos_type_tbl where rownum <
6;
v_postype varchar2(20);
v_description varchar2(50);
begin
open c_postype;
if c_postype%found then
dbms_output.put_line('found true');
elsif c_postype%found = false then
dbms_output.put_line('found false');
else
dbms_output.put_line('found null');
end if;
loop
fetch c_postype into v_postype,v_description ;
exit when c_postype%notfound;
dbms_output.put_line('postype:'||v_postype||',description:'||v_description);
end loop;
close c_postype;
dbms_output.put_line('---loop end---');
open c_postype;
fetch c_postype into v_postype,v_description;
while c_postype%found loop
dbms_output.put_line('postype:'||v_postype||',description:'||v_description);
fetch c_postype into v_postype,v_description ;
end loop;
close c_postype;
dbms_output.put_line('---while end---');
for v_pos in c_postype loop
v_postype := v_pos.pos_type;
v_description := v_pos.description;
dbms_output.put_line('postype:'||v_postype||',description:'||v_description);
end loop;
dbms_output.put_line('---for end---');
end;
create or replace procedure proccycle(p varchar2) as cursor c_postype is select pos_type, description from pos_type_tbl where rownum < 6; v_postype varchar2(20); v_description varchar2(50); begin open c_postype; if c_postype%found then dbms_output.put_line('found true'); elsif c_postype%found = false then dbms_output.put_line('found false'); else dbms_output.put_line('found null'); end if; loop fetch c_postype into v_postype,v_description ; exit when c_postype%notfound; dbms_output.put_line('postype:'||v_postype||',description:'||v_description); end loop; close c_postype; dbms_output.put_line('---loop end---'); open c_postype; fetch c_postype into v_postype,v_description; while c_postype%found loop dbms_output.put_line('postype:'||v_postype||',description:'||v_description); fetch c_postype into v_postype,v_description ; end loop; close c_postype; dbms_output.put_line('---while end---'); for v_pos in c_postype loop v_postype := v_pos.pos_type; v_description := v_pos.description; dbms_output.put_line('postype:'||v_postype||',description:'||v_description); end loop; dbms_output.put_line('---for end---'); end;
使用游标之前需要开打游标,open cursor,循环完后再关闭游标close cursor.
这是使用游标应该慎记于心的法则。
上面的过程演示了游标循环的三种方法。
在讨论循环方法之前,我们先看看%found和%notfound这些游标的属性。
open c_postype;
if c_postype%found then
dbms_output.put_line('found true');
elsif c_postype%found = false then
dbms_output.put_line('found false');
else
dbms_output.put_line('found null');
end if;
open c_postype; if c_postype%found then dbms_output.put_line('found true'); elsif c_postype%found = false then dbms_output.put_line('found false'); else dbms_output.put_line('found null'); end if;
在打开一个游标之后,马上检查它的%found或%notfound属性,它得到的结果即不是true也不是false.而是null.必须执行一条fetch语句后,这些属性才有值。
第一种使用loop 循环
loop
fetch c_postype into v_postype,v_description ;
exit when c_postype%notfound;
……
end loop
loop fetch c_postype into v_postype,v_description ; exit when c_postype%notfound; …… end loop
这里需要注意,exit when语句一定要紧跟在fetch之后。必避免多余的数据处理。
处理逻辑需要跟在exit when之后。这一点需要多加小心。
循环结束后要记得关闭游标。
第二种使用while循环。
fetch c_postype into v_postype,v_description;
while c_postype%found loop
……
fetch c_postype into v_postype,v_description ;
end loop;
fetch c_postype into v_postype,v_description; while c_postype%found loop …… fetch c_postype into v_postype,v_description ; end loop;
我们知道了一个游标打开后,必须执行一次fetch语句,游标的属性才会起作用。所以使用while 循环时,就需要在循环之前进行一次fetch动作。
而且数据处理动作必须放在循环体内的fetch方法之前。循环体内的fetch方法要放在最后。否则就会多处理一次。这一点也要非常的小心。
总之,使用while来循环处理游标是最复杂的方法。
第三种 for循环
for v_pos in c_postype loop
v_postype := v_pos.pos_type;
v_description := v_pos.description;
…
end loop;
for v_pos in c_postype loop v_postype := v_pos.pos_type; v_description := v_pos.description; … end loop;
可见for循环是比较简单实用的方法。
首先,它会自动open和close游标。解决了你忘记打开或关闭游标的烦恼。
其它,自动定义了一个记录类型及声明该类型的变量,并自动fetch数据到这个变量中。
我们需要注意v_pos 这个变量无需要在循环外进行声明,无需要为其指定数据类型。
它应该是一个记录类型,具体的结构是由游标决定的。
这个变量的作用域仅仅是在循环体内。
把v_pos看作一个记录变量就可以了,如果要获得某一个值就像调用记录一样就可以了。
如v_pos.pos_type
由此可见,for循环是用来循环游标的最好方法。高效,简洁,安全。
但遗憾的是,常常见到的却是第一种方法。所以从今之后得改变这个习惯了。
3.4 select into不可乎视的问题
我们知道在pl/sql中要想从数据表中向变量赋值,需要使用select into 子句。
但是它会带动来一些问题,如果查询没有记录时,会抛出no_data_found异常。
如果有多条记录时,会抛出too_many_rows异常。
这个是比较糟糕的。一旦抛出了异常,就会让过程中断。特别是no_data_found这种异常,没有严重到要让程序中断的地步,可以完全交给由程序进行处理。
create or replace procedure procexception(p varchar2)
as
v_postype varchar2(20);
begin
select pos_type into v_postype from pos_type_tbl where 1=0;
dbms_output.put_line(v_postype);
end;
create or replace procedure procexception(p varchar2) as v_postype varchar2(20); begin select pos_type into v_postype from pos_type_tbl where 1=0; dbms_output.put_line(v_postype); end;
执行这个过程
SQL> exec procexception('a');
报错
ORA-01403: no data found
ORA-06512: at
"LIFEMAN.PROCEXCEPTION", line
6
ORA-06512: at line
1
SQL> exec procexception('a'); 报错 ORA-01403: no data found ORA-06512: at "LIFEMAN.PROCEXCEPTION", line 6 ORA-06512: at line 1
处理这个有三个办法
1. 直接加上异常处理。
create or replace procedure procexception(p varchar2)
as
v_postype varchar2(20);
begin
select pos_type into v_postype from pos_type_tbl where 1=0;
dbms_output.put_line(v_postype);
exception
when no_data_found then
dbms_output.put_line('没找到数据');
end;
create or replace procedure procexception(p varchar2) as v_postype varchar2(20); begin select pos_type into v_postype from pos_type_tbl where 1=0; dbms_output.put_line(v_postype); exception when no_data_found then dbms_output.put_line('没找到数据'); end;
这样做换汤不换药,程序仍然被中断。可能这样不是我们所想要的。
2. select into做为一个独立的块,在这个块中进行异常处理
create or replace procedure procexception(p varchar2)
as
v_postype varchar2(20);
begin
begin
select pos_type into v_postype from pos_type_tbl where 1=0;
dbms_output.put_line(v_postype);
exception
when no_data_found then
v_postype := '';
end;
dbms_output.put_line(v_postype);
end;
create or replace procedure procexception(p varchar2) as v_postype varchar2(20); begin begin select pos_type into v_postype from pos_type_tbl where 1=0; dbms_output.put_line(v_postype); exception when no_data_found then v_postype := ''; end; dbms_output.put_line(v_postype); end;
这是一种比较好的处理方式了。不会因为这个异常而引起程序中断。
3.使用游标
create or replace procedure procexception(p varchar2)
as
v_postype varchar2(20);
cursor c_postype is select pos_type from pos_type_tbl where
1=0;
begin
open c_postype;
fetch c_postype into v_postype;
close c_postype;
dbms_output.put_line(v_postype);
end;
create or replace procedure procexception(p varchar2) as v_postype varchar2(20); cursor c_postype is select pos_type from pos_type_tbl where 1=0; begin open c_postype; fetch c_postype into v_postype; close c_postype; dbms_output.put_line(v_postype); end;
这样就完全的避免了no_data_found异常。完全交由程序员来进行控制了。
第二种情况是too_many_rows 异常的问题。
Too_many_rows 这个问题比起no_data_found要复杂一些。
给一个变量赋值时,但是查询结果有多个记录。
处理这种问题也有两种情况:
1. 多条数据是可以接受的,也就是说从结果集中随便取一个值就行。这种情况应该很极端了吧,如果出现这种情况,也说明了程序的严谨性存在问题。
2. 多条数据是不可以被接受的,在这种情况肯定是程序的逻辑出了问题,也说是说原来根本就不会想到它会产生多条记录。
对于第一种情况,就必须采用游标来处理,而对于第二种情况就必须使用内部块来处理,重新抛出异常。
多条数据可以接受,随便取一条,这个跟no_data_found的处理方式一样,使用游标。
我这里仅说第二种情况,不可接受多条数据,但是不要忘了处理no_data_found哦。这就不能使用游标了,必须使用内部块。
create or replace procedure procexception2(p varchar2)
as
v_postype varchar2(20);
begin
begin
select pos_type into v_postype from pos_type_tbl where rownum <
5;
exception
when no_data_found then
v_postype :=null;
when too_many_rows then
raise_application_error(-20000,'对v_postype赋值时,找到多条数据');
end;
dbms_output.put_line(v_postype);
end;
create or replace procedure procexception2(p varchar2) as v_postype varchar2(20); begin begin select pos_type into v_postype from pos_type_tbl where rownum < 5; exception when no_data_found then v_postype :=null; when too_many_rows then raise_application_error(-20000,'对v_postype赋值时,找到多条数据'); end; dbms_output.put_line(v_postype); end;
需要注意的是一定要加上对no_data_found的处理,对出现多条记录的情况则继续抛出异常,让上一层来处理。
总之对于select into的语句需要注意这两种情况了。需要妥当处理啊。
3.5 在存储过程中返回结果集 我们使用存储过程都是返回值都是单一的,有时我们需要从过程中返回一个集合。即多条数据。这有几种解决方案。比较简单的做法是写临时表,但是这种做法不灵活。而且维护麻烦。我们可以使用嵌套表来实现.没有一个集合类型能够与java的jdbc类型匹配。这就是对象与关系数据库的阻抗吧。数据库的对象并不能够完全转换为编程语言的对象,还必须使用关系数据库的处理方式 |
相关文章推荐
- java中使用ibatis来调用存储过程(上)
- 编写存储过程并使用java代码调用
- 编写存储过程,并且使用java代码调用存储过程的简单例子
- Java中使用ibatis调用Oracle存储过程和函数
- java代码在ibatis里调用存储过程配置
- 使用 iBatis 调用存储过程并返回值
- java代码在ibatis里调用存储过程配置
- IBatis.Net使用总结(四)-- IBatis 调用存储过程
- java调用oracle 存储过程 以及游标使用
- 编写存储过程返回的结果集在游标中使用java代码调用
- Java中使用反射调用静态方法
- ibatis通过Map封装参数调用存储过程
- java调用存储过程
- 使用nhibernate调用存储过程实现多返回值
- Android使用百度地图SDK调用百度地图"java.lang.UnsatisfiedLinkError: Native method not found: com.baidu.platform."
- mysql存储过程学习及java调用存储过程
- Java调用MySQL存储过程
- java调用存储过程
- 使用JNI,让java调用c代码
- Windows下使用Java Jni调用C/C++初探